Pilot operated check valve CPOM2DDV is a genuine Parker product for the hydraulic systems.
A pilot operated check valve (hydraulic lock) shuts the lines of a cylinder or motor without leakage and stops the load moving on its own. The Parker CPOM series are sandwich plate valves fitted between a directional valve and its subplate; the CPOM2DDV has a CETOP 3 (NG6, NFPA D03) interface. Ports A and B each carry a check valve: oil flows freely towards the consumer, while the check valve in the return line is opened by a pilot piston to allow the return flow. With the directional valve in neutral, the cylinder is therefore locked in both directions. The letter V at the end of the code stands for FKM seals. A locked cylinder that creeps slowly points to a dirty or worn check valve seat. Choose the valve by its model code. Fit the valve on the CETOP 3 interface with new O-rings and clamp it with longer bolts.
Specifications
| Part number | CPOM2DDV |
| Manufacturer | Parker |
| Production type | Original |
| Part type | Pilot operated check valve |
| System / group | Hydraulic system |
Compatibility
Other parts are in Hydraulic pumps.
Fitting
Check the coil voltage and connector type before fitting, and make sure the mounting face is unscratched. Check the sealing after fitting.